1.
Proc Natl Acad Sci U S A ; 121(17): e2315696121, 2024 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-38640344

RESUMEN

Quantum amplification enables the enhancement of weak signals and is of great importance for precision measurements, such as biomedical science and tests of fundamental symmetries. Here, we observe a previously unexplored magnetic amplification using dark noble-gas nuclear spins in the absence of pump light. Such dark spins exhibit remarkable coherence lasting up to 6 min and the resilience against the perturbations caused by overlapping alkali-metal gas. We demonstrate that the observed phenomenon, referred to as "dark spin amplification," significantly magnifies magnetic field signals by at least three orders of magnitude. As an immediate application, we showcase an ultrasensitive magnetometer capable of measuring subfemtotesla fields in a single 500-s measurement. Our approach is generic and can be applied to a wide range of noble-gas isotopes, and we discuss promising optimizations that could further improve the current signal amplification up to [Formula: see text] with [Formula: see text]Ne, [Formula: see text] with [Formula: see text]Xe, and [Formula: see text] with [Formula: see text]He. This work unlocks opportunities in precision measurements, including searches for ultralight dark matter with sensitivity well beyond the supernova-observation constraints.

2.
Rev Sci Instrum ; 95(4)2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38557888

RESUMEN

This paper presents a new technique to study the adsorption and desorption of ions and electrons on insulating surfaces in the presence of strong electric fields in cryoliquids. The experimental design consists of a compact cryostat coupled with a sensitive electro-optical Kerr device to monitor the stability of the electric fields. The behavior of nitrogen and helium ions on a poly(methyl methacrylate) (PMMA) surface was compared to a PMMA surface coated with a mixture of deuterated polystyrene and deuterated polybutadiene. Ion accumulation and removal on these surfaces were unambiguously observed. Within the precision of the data, both surfaces behave similarly for the physisorbed ions. The setup was also used to measure the (quasi-)static dielectric constant of PMMA at T ≈ 70 K. The impact of the ion adsorption on the search for a neutron permanent electric dipole moment in a cryogenic environment, such as the nEDM@SNS experiment, is discussed.

3.
Anal Chem ; 95(49): 17997-18005, 2023 12 12.
Artículo en Inglés | MEDLINE | ID: mdl-38047582

RESUMEN

We demonstrate that enzyme-catalyzed reactions can be observed in zero- and low-field NMR experiments by combining recent advances in parahydrogen-based hyperpolarization methods with state-of-the-art magnetometry. Specifically, we investigated two model biological processes: the conversion of fumarate into malate, which is used in vivo as a marker of cell necrosis, and the conversion of pyruvate into lactate, which is the most widely studied metabolic process in hyperpolarization-enhanced imaging. In addition to this, we constructed a microfluidic zero-field NMR setup to perform experiments on microliter-scale samples of [1-13C]fumarate in a lab-on-a-chip device. Zero- to ultralow-field (ZULF) NMR has two key advantages over high-field NMR: the signals can pass through conductive materials (e.g., metals), and line broadening from sample heterogeneity is negligible. To date, the use of ZULF NMR for process monitoring has been limited to studying hydrogenation reactions. In this work, we demonstrate this emerging analytical technique for more general reaction monitoring and compare zero- vs low-field detection.


Asunto(s)
Imagen por Resonancia Magnética , Ácido Pirúvico , Espectroscopía de Resonancia Magnética/métodos , Imagen por Resonancia Magnética/métodos , Hidrogenación , Ácido Pirúvico/metabolismo , Fumaratos
5.
J Phys Chem Lett ; 14(30): 6814-6822, 2023 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-37486855

RESUMEN

Photochemically induced dynamic nuclear polarization (photo-CIDNP) enables nuclear spin ordering by irradiating samples with light. Polarized spins are conventionally detected via high-field chemical-shift-resolved NMR (above 0.1 T). In this Letter, we demonstrate in situ low-field photo-CIDNP measurements using a magnetically shielded fast-field-cycling NMR setup detecting Larmor precession via atomic magnetometers. For solutions comprising mM concentrations of the photochemically polarized molecules, hyperpolarized 1H magnetization is detected by pulse-acquired NMR spectroscopy. The observed NMR line widths are about 5 times narrower than normally anticipated in high-field NMR and are systematically affected by light irradiation during the acquisition period, reflecting a reduction of the transverse relaxation time constant, T2*, on the order of 10%. Magnetometer-detected photo-CIDNP spectroscopy enables straightforward observation of spin-chemistry processes in the ambient field range from a few nT to tens of mT. Potential applications of this measuring modality are discussed.

6.
Chem Commun (Camb) ; 59(62): 9509-9512, 2023 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-37450281

RESUMEN

We show that catalyst-free aqueous solutions of hyperpolarized [1-13C]succinate can be produced using parahydrogen-induced polarization (PHIP) and a combination of homogeneous and heterogeneous catalytic hydrogenation reactions. We generate hyperpolarized [1-13C]fumarate via PHIP using para-enriched hydrogen gas with a homogeneous ruthenium catalyst, and subsequently remove the toxic catalyst and reaction side products via a purification procedure. Following this, we perform a second hydrogenation reaction using normal hydrogen gas to convert the fumarate into succinate using a solid Pd/Al2O3 catalyst. This inexpensive polarization protocol has a turnover time of a few minutes, and represents a major advance for in vivo applications of [1-13C]succinate as a hyperpolarized contrast agent.

7.
Phys Rev Lett ; 130(25): 251002, 2023 Jun 23.
Artículo en Inglés | MEDLINE | ID: mdl-37418735

RESUMEN

The effects of scalar and pseudoscalar ultralight bosonic dark matter (UBDM) were searched for by comparing the frequency of a quartz oscillator to that of a hyperfine-structure transition in ^{87}Rb, and an electronic transition in ^{164}Dy. We constrain linear interactions between a scalar UBDM field and standard-model (SM) fields for an underlying UBDM particle mass in the range 1×10^{-17}-8.3×10^{-13} eV and quadratic interactions between a pseudoscalar UBDM field and SM fields in the range 5×10^{-18}-4.1×10^{-13} eV. Within regions of the respective ranges, our constraints on linear interactions significantly improve on results from previous, direct searches for oscillations in atomic parameters, while constraints on quadratic interactions surpass limits imposed by such direct searches as well as by astrophysical observations.

8.
Opt Lett ; 48(10): 2512-2514, 2023 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-37186695

RESUMEN

We present a design to increase the amount of collected fluorescence emitted by nitrogen-vacancy color centers in diamond used for quantum-sensing. An improvement was measured in collected fluorescence when comparing oppositely faced emitting surfaces by a factor of 3.8(1). This matches ray-tracing simulation results. This design therefore improves on the shot noise limited sensitivity in optical readout-based measurements of, for instance, magnetic and electric fields, pressure, temperature, and rotations.

9.
Phys Rev Lett ; 130(13): 133202, 2023 Mar 31.
Artículo en Inglés | MEDLINE | ID: mdl-37067299

RESUMEN

The existence of exotic spin-dependent forces may shine light on new physics beyond the standard model. We utilize two iron shielded SmCo_{5} electron-spin sources and two optically pumped magnetometers to search for exotic long-range spin-spin velocity-dependent force. The orientations of spin sources and magnetometers are optimized such that the exotic force is enhanced and common-mode noise is effectively subtracted. We set direct limit on proton-electron interaction in the force range from 1 cm to 1 km. Our experiment represents more than 10 orders of magnitude improvement than previous works.

10.
Phys Rev Lett ; 130(15): 153601, 2023 Apr 14.
Artículo en Inglés | MEDLINE | ID: mdl-37115859

RESUMEN

We demonstrate an alignment-based ^{87}Rb magnetometer that is immune to nonlinear Zeeman (NLZ) splitting, addressing an important problem in alkali-metal atomic magnetometry. In our scheme, there is a single magnetic resonance peak and well-separated hyperfine transition frequencies, making the magnetometer insensitive or even immune to NLZ-related heading errors. It is shown that the magnetometer can be implemented for practical measurements in geomagnetic environments, and the photon-shot-noise-limited sensitivity reaches 9 fT/sqrt[Hz] at 5 µT and remains at tens of fT/sqrt[Hz] at 50 µT at room temperature.

11.
Phys Rev Lett ; 130(6): 063201, 2023 Feb 10.
Artículo en Inglés | MEDLINE | ID: mdl-36827554

RESUMEN

Achieving high energy resolution in spin systems is important for fundamental physics research and precision measurements, with alkali-noble-gas comagnetometers being among the best available sensors. We found a new relaxation mechanism in such devices, the gradient of the Fermi-contact-interaction field that dominates the relaxation of hyperpolarized nuclear spins. We report on precise control over spin distribution, demonstrating a tenfold increase of nuclear spin hyperpolarization and transverse coherence time with optimal hybrid optical pumping. Operating in the self-compensation regime, our ^{21}Ne-Rb-K comagnetometer achieves an ultrahigh inertial rotation sensitivity of 3×10^{-8} rad/s/Hz^{1/2} in the frequency range from 0.2 to 1.0 Hz, which is equivalent to the energy resolution of 3.1×10^{-23} eV/Hz^{1/2}. We propose to use this comagnetometer to search for exotic spin-dependent interactions involving proton and neutron spins. The projected sensitivity surpasses the previous experimental and astrophysical limits by more than 4 orders of magnitude.

12.
Sci Adv ; 9(1): eade0353, 2023 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-36608126

RESUMEN

Quantum sensing provides sensitive tabletop tools to search for exotic spin-dependent interactions beyond the standard model, which have attracted great attention in theories and experiments. Here, we develop a technique based on Spin Amplifier for Particle PHysIcs REsearch (SAPPHIRE) to resonantly search for exotic interactions, specifically parity-odd spin-spin interactions. The present technique effectively amplifies exotic interaction fields by a factor of about 200 while being insensitive to spurious magnetic fields. Our studies, using such a quantum amplification technique, explore the parity-violation interactions mediated by a new vector boson in the challenging parameter space (force range between 3 mm and 1 km) and set the most stringent constraints on axial-vector electron-neutron couplings, substantially improving previous limits by five orders of magnitude. Moreover, our constraints on axial-vector couplings between nucleons reach into a hitherto unexplored parameter space. The present constraints complement the existing astrophysical and laboratory studies on potential standard model extensions.

13.
Chem Rev ; 123(4): 1417-1551, 2023 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-36701528

RESUMEN

Magnetic resonance techniques are successfully utilized in a broad range of scientific disciplines and in various practical applications, with medical magnetic resonance imaging being the most widely known example. Currently, both fundamental and applied magnetic resonance are enjoying a major boost owing to the rapidly developing field of spin hyperpolarization. Hyperpolarization techniques are able to enhance signal intensities in magnetic resonance by several orders of magnitude, and thus to largely overcome its major disadvantage of relatively low sensitivity. This provides new impetus for existing applications of magnetic resonance and opens the gates to exciting new possibilities. In this review, we provide a unified picture of the many methods and techniques that fall under the umbrella term "hyperpolarization" but are currently seldom perceived as integral parts of the same field. Specifically, before delving into the individual techniques, we provide a detailed analysis of the underlying principles of spin hyperpolarization. We attempt to uncover and classify the origins of hyperpolarization, to establish its sources and the specific mechanisms that enable the flow of polarization from a source to the target spins. We then give a more detailed analysis of individual hyperpolarization techniques: the mechanisms by which they work, fundamental and technical requirements, characteristic applications, unresolved issues, and possible future directions. We are seeing a continuous growth of activity in the field of spin hyperpolarization, and we expect the field to flourish as new and improved hyperpolarization techniques are implemented. Some key areas for development are in prolonging polarization lifetimes, making hyperpolarization techniques more generally applicable to chemical/biological systems, reducing the technical and equipment requirements, and creating more efficient excitation and detection schemes. We hope this review will facilitate the sharing of knowledge between subfields within the broad topic of hyperpolarization, to help overcome existing challenges in magnetic resonance and enable novel applications.

14.
Anal Chem ; 95(2): 720-729, 2023 01 17.
Artículo en Inglés | MEDLINE | ID: mdl-36563171

RESUMEN

Zero- to ultralow-field nuclear magnetic resonance is a modality of magnetic resonance experiment which does not require strong superconducting magnets. Contrary to conventional high-field nuclear magnetic resonance, it has the advantage of allowing high-resolution detection of nuclear magnetism through metal as well as within heterogeneous media. To achieve high sensitivity, it is common to couple zero-field nuclear magnetic resonance with hyperpolarization techniques. To date, the most common technique is parahydrogen-induced polarization, which is only compatible with a small number of compounds. In this article, we establish dissolution dynamic nuclear polarization as a versatile method to enhance signals in zero-field nuclear magnetic resonance experiments on sample mixtures of [13C]sodium formate, [1-13C]glycine, and [2-13C]sodium acetate, and our technique is immediately extendable to a broad range of molecules with >1 s relaxation times. We find signal enhancements of up to 11,000 compared with thermal prepolarization in a 2 T permanent magnet. To increase the signal in future experiments, we investigate the relaxation effects of the TEMPOL radicals used for the hyperpolarization process at zero- and ultralow-fields.


Asunto(s)
Imagen por Resonancia Magnética , Solubilidad , Espectroscopía de Resonancia Magnética/métodos , Imagen por Resonancia Magnética/métodos
15.
Phys Rev Appl ; 19(6)2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38716475

RESUMEN

We measure electron- and nuclear-spin transition frequencies in the ground state of nitrogen-vacancy (N-V) centers in diamond for two nitrogen isotopes (14N-V and 15N-V) over temperatures ranging from 77 to 400 K. Measurements are performed using Ramsey interferometry and direct optical readout of the nuclear and electron spins. We extract coupling parameters Q (for 14N-V), D, A‖, A⊥, and γe/γn, and their temperature dependences for both isotopes. The temperature dependences of the nuclear-spin transitions within the ms=0 spin manifold near room temperature are found to be 0.52(1) ppm/K for 14N-V(|mI = -1⟩ ↔ |mI = +1⟩) and -1.1(1) ppm/K for 15N-V(|mI = -1/2⟩ ↔ |mI = +1/2⟩). An isotopic shift in the zero-field splitting parameter D between 14N-V and 15N-V is measured to be ~ 120 kHz. Residual transverse magnetic fields are observed to shift the nuclear-spin transition frequencies, especially for 15N-V. We have precisely determined the set of parameters relevant for the development of nuclear-spin-based diamond quantum sensors with greatly reduced sensitivity to environmental factors.

16.
Sci Adv ; 8(48): eade1613, 2022 Dec 02.
Artículo en Inglés | MEDLINE | ID: mdl-36449621

RESUMEN

Quantum sensing with solid-state electron spin systems finds broad applications in diverse areas ranging from material and biomedical sciences to fundamental physics. Exploiting collective behavior of noninteracting spins holds the promise of pushing the detection limit to even lower levels, while to date, those levels are scarcely reached because of the broadened linewidth and inefficient readout of solid-state spin ensembles. Here, we experimentally demonstrate that such drawbacks can be overcome by a reborn maser technology at room temperature in the solid state. Owing to maser action, we observe a fourfold reduction in the electron paramagnetic resonance linewidth of an inhomogeneously broadened molecular spin ensemble, which is narrower than the same measured from single spins at cryogenic temperatures. The maser-based readout applied to near zero-field magnetometry showcases the measurement signal-to-noise ratio of 133 for single shots. This technique would be an important addition to the toolbox for boosting the sensitivity of solid-state ensemble spin sensors.

17.
Nat Commun ; 13(1): 7387, 2022 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-36450723

RESUMEN

Experimental searches for exotic spin-dependent forces are attracting a lot of attention because they allow to test theoretical extensions to the standard model. Here, we report an experimental search for possible exotic spin-dependent force, specifically spin-and-velocity-dependent forces, by using a K-Rb-21Ne co-magnetometer and a tungsten ring featuring a high nucleon density. Taking advantage of the high sensitivity of the co-magnetometer, the pseudomagnetic field from this exotic force is measured to be ≤7 aT. This sets limits on coupling constants for the neutron-nucleon and proton-nucleon interactions in the range of ≥0.1 m (mediator boson mass ≤2 µeV). The coupling constant limits are established to be [Formula: see text] and [Formula: see text], which are more than one order of magnitude tighter than astronomical and cosmological limits on the coupling between the new gauge boson such as Z' and standard model particles.

18.
Phys Rev Lett ; 129(5): 051801, 2022 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-35960560

RESUMEN

Searches for the axion and axionlike particles may hold the key to unlocking some of the deepest puzzles about our Universe, such as dark matter and dark energy. Here, we use the recently demonstrated spin-based amplifier to constrain such hypothetical particles within the well-motivated "axion window" (10 µeV-1 meV) through searching for an exotic dipole-dipole interaction between polarized electron and neutron spins. The key ingredient is the use of hyperpolarized long-lived ^{129}Xe nuclear spins as an amplifier for the pseudomagnetic field generated by the exotic interaction. Using such a spin sensor, we obtain a direct upper bound on the product of coupling constants g_{p}^{e}g_{p}^{n}. The spin-based amplifier technique can be extended to searches for a wide variety of hypothetical particles beyond the standard model.

19.
Biomed Tech (Berl) ; 67(5): 333-344, 2022 Oct 26.
Artículo en Inglés | MEDLINE | ID: mdl-35960879

RESUMEN

Transcranial magnetic stimulation (TMS) has widespread clinical applications from diagnosis to treatment. We combined TMS with non-contact magnetic detection of TMS-evoked muscle activity in peripheral limbs to explore a new diagnostic modality that enhances the utility of TMS as a clinical tool by leveraging technological advances in magnetometry. We recorded measurements in a regular hospital room using an array of optically pumped magnetometers (OPMs) inside a portable shield that encloses only the forearm and hand of the subject. We present magnetomyograms (MMG)s of TMS-evoked movement in a human hand, together with a simultaneous surface electromyograph (EMG) data. The biomagnetic signals recorded in the MMG provides detailed spatial and temporal information that is complementary to that of the electric signal channels. Moreover, we identify features in the magnetic recording beyond that of the EMG. This system demonstrates the value of biomagnetic signals in TMS-based clinical approaches and widens its availability and practical potential.


Asunto(s)
Movimiento , Estimulación Magnética Transcraneal , Electromiografía , Potenciales Evocados Motores/fisiología , Mano/fisiología , Humanos , Movimiento/fisiología
20.
Phys Rev Lett ; 129(3): 031301, 2022 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-35905361

RESUMEN

We present a search for fundamental constant oscillations in the range 20 kHz-100 MHz that may arise within models for ultralight dark matter (UDM). Using two independent optical-spectroscopy apparatuses, we achieve up to ×1000 greater sensitivity in the search relative to previous work [D. Antypas et al., Phys. Rev. Lett. 123, 141102 (2019).PRLTAO0031-900710.1103/PhysRevLett.123.141102]. We report no observation of UDM and thus constrain respective couplings to electrons and photons within the investigated UDM particle mass range 8×10^{-11}-4×10^{-7} eV. The constraints significantly exceed previously set bounds from atomic spectroscopy and, as we show, may surpass in future experiments those provided by equivalence-principle (EP) experiments in a specific case regarding the combination of UDM couplings probed by the EP experiments.